Caring for your GIPskins

GIP Skin Cleaning Care Flyer

GIPskins Cleaning and Decontamination

There are a vast number of cleaning and disinfection systems on the market, and while many are compatible with GIPskins PPE (Using Dartex Coatings’ fabrics), some are not.

The following is a summary of the different cleaning and disinfecting methods discussed in the CDC Guideline for Disinfection and Sterilisation in Healthcare facilities, 2008, and in the, MHRA MAC Manual, and comments regarding the impact these methods have on GIPskins’ fabric.

Decontamination/Sterilisation: Must be applied only on cleaned surfaces and thoroughly rinsed afterwards.

We recommend that products are rinsed with clean water after cleaning or disinfecting

  • To prevent build-up of residual cleaning chemicals which may compromise GIPskins PPE biocompatibility.
  • To prevent build-up of residual cleaning chemicals, leading to cleaning with a higher concentration than recommended and possibly damaging the cover.
  • To prevent the formation of abrasive crystals that can abrade the product surface both in use and in subsequent cleaning.

    Products should be thoroughly dried before returning to use or being placed in storage. This is because the cleaning and rinsing process swells the polyurethane coating, making it more susceptible to physical damage.

    Please note that disinfectants should be used as per the manufacturer’s instructions to avoid breaches of FIFRA. (The Federal Insecticide, Fungicide, Rodenticide Act)

    Note: GIPskins are classified as “non-critical” under the CDC guidelines, as they are not placed in vivo or in prolonged contact with non-intact skin or mucous membranes.

Cleaning:

Ref: MAC Manual June 2006 part 3 p33/37

This recommends that GIPskins PPE are regularly cleaned “as part of a routine and following patient use. Rinsed thoroughly and dry. GIPskins PPE should be enclosed in a waterproof cover and routinely inspected for damage”. See also p36.

Cleaning may be effected either by mechanical means at 71 degrees C to 95 degrees C dependent upon Dartex product type, or by using a manual wiping process. A neutral detergent is suitable for this task and the Cleaning (manual) – non-immersion section (MAC Part 2 p20) describes the full method.

Alcohol, if allowed to ‘pool’, may result in temporary swelling of the cover making it more prone to mechanical damage.